    CF-2 Alkyd Red Lead Anti-Rust Paint
    • CF-2 Alkyd Red Lead Anti-Rust Paint
    • Specifications
      • Product Name:CF-2 Alkyd Red Lead Anti-Rust Paint
      • Product Number:CF-2
      • 分享到:
    • Details
    • Product Description

      It is composed by alkyd resin, red lead powder, extender pigment, desiccant and solvent, with good anti-rust property, rapid drying and hard paint film.


      Design Purpose 

      Priming and rust resistance on the surface of black metal in the slight and medium corrosive industrial environment, being inapplicable for underwater position.


      Physical Parameters

      Color

      Nacarat

       

      Luster

      Lightless

       

      Theoretical spreading rate

      180g/m2, 11.10m2/L (calculated in 40μm dry film, excluding the loss)

       

      Specific gravity:

      About 2.0

       

      Drying time

      23±2℃: surface dryness≦4h, solid dryness≦24h

       

      Flash point

      38℃

       

      Storage period

      12 months

      Construction Instruction

      Mixing ratio

      Canned by single pot


      Maturing time

      Use immediately after opening and stirring uniformly


      Service life

      Unlimit


      Construction method

      Manual painting;  roller coating  


      Diluent

      X-6 Alkyd coating diluent


      Maximal dilution amount

      5%


      Tool washing

      X-6 Alkyd coating diluent


      Film coating thickness

      Wet film: 95μm                     Dry film: 60μm


      Coating interval

      Temperature of substrate

      5℃

      20℃

      30℃

      Shortest

      48h

      24h

      12h

      Longest

      Unlimit

       


      Surface treatment

      *If it is coated directly on the steel, the steel is required to be subjected to shot blasting or sandblasting treatment  so as to reach Grade Sa2 of Sweden Derusting Standard, or the manual derusting reaches  Grade St3;

      *The primer surface in the workWorkshop is required to be subjected to secondary derusting so as to reach Grade St3 of Sweden Derusting Standard.


      Construction condition

      The temperature of substrate must be 3℃ higher than dewing point, and the relative humidity must be less than 85%.

       

      Finishing paint

      Alkyd enamel paint,alkyd tempered paint;alkyd rusty red anti-rust paint, Alkyd micaceous iron anti-rust paint.

      Packing Specification

      25Kg/20L per barrel

      Considerations

      *This coating contains the heavy pigment particle, while constructing , this coating can be utilized after uniformly stirring thoroughly;

      *There is red lead inside paint film, it is inadvisable to be used in the sealed cabin where the fire work calibration must be conducted so as to prevent lead poisoning;

      *The red lead paint film is inadvisable to expose in the air for long term, otherwise, the paint film easily whitens or discolors.

      Safety guide  

      Avoid breathing solvent steam or paint fog for a long term; the skin and eye can’t contact this product; while constructing in the narrow place or poorly ventilated place, the forced ventilation must be provided; while constructing, the protective articles should be worn.

      Annotation

      *Above-said thickness of dry film and wet film refers to the index while implementing the high-pressure siphon spray;

      *Relevant data in this instruction is obtained from laboratory, the actual product may be slightly different from it;

      *If above data is changed, the data is based on the latest instruction, without prior notification.

    Tags:
    |新168幸运飞飞艇